Horse Construction menawarkan rangkaian lengkap material perkuatan struktur dengan dukungan teknis, dukungan dokumentasi, dukungan produk, dukungan perangkat lunak, dukungan proyek.
2) wall seismic capacity of the braced girder can not meet the requirements, can be added for masonry columns, column, reinforced concrete column or the mortar layer, method of reinforcing steel net wall.
1) window wall width is too small or seismic capacity can not meet the requirements, can be added for reinforced concrete frame or reinforced by cement mortar, method of reinforced wall.
2) wall seismic capacity of the braced girder can not meet the requirements, can be added for masonry columns, column, reinforced concrete column or the mortar layer, method of reinforcing steel net wall.
3) when the wall of the cantilever member does not meet the requirements of identification, it is appropriate to reinforce the end of the cantilever member by adding reinforced concrete columns or masonry composite columns.
4) there is no tie up or no knot in the partition wall. It can be strengthened by trimming, embedding steel jacket, anchor bar or steel tie bar. When the partition wall is too long and too high, it can be reinforced with steel mesh mortar surface.
5) when the roof stairwell, the elevator room and the water tank do not meet the requirements of appraisal, they can be strengthened by surface or additional columns. The upper part should have reliable connection with the roof components, and the lower part should be connected with the reinforcement measures of the main structure.
6) a roof of the chimney, no Rachel parapet, Menlian exceeding the prescribed height, should be removed, or by reducing the height of steel reinforcement, steel rod.
7) when the anchorage length of the cantilever member is not satisfied, the pull rod can be added or the length of the cantilever can be reduced.