Externally bonded CFRP sheet on concrete and masonry structure

The difference between the masonry structure and the concrete structure of externally bonding carbon fiber reinfroced polymer(CFRP) sheet:Substrate difference,Material surface difference,Construction methods difference

The difference between the masonry structure and the concrete structure of externally bonding carbon fiber reinfroced polymer(CFRP) sheet:


CFRP sheet on concrete and  masonry structure


1.Substrate difference

When the masonry structure is bonded with carbon fiber cloth, the base material is made up of two materials, brick and mortar, because masonry building is built by single brick and mortar, and the saturation of mortar can not be effectively controlled, and its integrity and quality are poor.

When the concrete structure is bonded with carbon fiber cloth, the base material is concrete, and the concrete is the engineering composite material cemented by cementitious material to aggregate. The concrete can be regarded as homogeneous and continuous material, and has good integrity.


CFRP sheet on concrete and  masonry structure


2.Material surface difference

Masonry structure is composed of a large number of bricks and mortar piled up, the structure of the existence of a large number of mortar, mortar mortar between the full degree of inconsistency, and different block strength are not the same, no unified evaluation of its surface strength, can only be used to determine the surface strength of brick and mortar. In general, the surface strength of the masonry structure is not as good as the surface strength of the concrete structure.

High strength concrete structure surface, according to the GB50367-2013 "reinforced concrete structure design specification" set when the concrete CFRP reinforcement when the concrete surface strength of not less than C15, and the concrete surface tensile bond strength shall not be less than 1.5MPa.


CFRP sheet on concrete and  masonry structure


3.Construction methods difference

When the masonry structure reinforced with carbon fiber, the surface defects of the masonry structure needs to be repaired, and then on the wall and column surface must first do a layer of cement mortar screeding layer, the layer thickness should not be less than 15mm and flat, the strength of cement mortar shall not be less than M10, the smooth curved layer after curing, in accordance with the method paste carbon fiber to concrete structure construction.

When the carbon fiber cloth and concrete structure, need to be polished with new reinforced concrete, loose concrete removed, clean the surface of concrete member and yang angle round process, there will be defects repaired, and then paste the carbon fiber cloth construction.


Produk Teranjum Horse Construction

Anda dapat menemukan segala yang Anda butuhkan di sini. Percayalah dan cobalah produk - produk ini, Anda akan menemukan perbedaan yang besar setelah itu.

Lembaran Serat Karbon Unidirectional HM-20

Lembaran serat karbon Horse Construction digunakan untuk perkuatan struktural, perbaikan, dan perbaikan substrat beton, pasangan bata, baja, dan kayu pada bangunan, jembatan, jalan raya, rel kereta api, terowongan, dermaga, dan bandara sipil.

Lebih Banyak >

Primer Serat Karbon HM-180

Primer serat karbon dengan viskositas rendah dan penetrasi kuat untuk permukaan beton bertulang guna meningkatkan bagian yang cacat

Lebih Banyak >

Perekat Serat Karbon HM-180C3P

Viskositas rendah, impregnasi yang baik, dengan sifat tiksotropik tertentu, digunakan untuk impregnasi dan pasta permukaan komponen yang diperkuat dan produk serat. Peran perekat serat karbon Horse adalah untuk sepenuhnya meresap ke dalam produk serat, dan

Lebih Banyak >

Back
Top
Close